J T BAKER INC -- AMMONIUM DICHROMATE, 0690 -- 6810-00N059750
=====================  Product Identification  =====================

Product ID:AMMONIUM DICHROMATE, 0690
MSDS Date:09/07/1989
FSC:6810
NIIN:00N059750
=== Responsible Party ===
Company Name:J T BAKER INC
Address:222 RED SCHOOL LANE
City:PHILLIPSBURG
State:NJ
ZIP:08865
Country:US
Info Phone Num:201-859-2151
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:DO803
=== Contractor Identification ===
Company Name:J T BAKER INC
Address:222 RED SCHOOL LANE
City:PHILLIPSBURG
State:NJ
ZIP:08865
Country:US
Phone:1-800-582-2537
CAGE:DO803
Company Name:MALLINCKRODT BAKER,  INC.
Address:222 RED SCHOOL LANE
Box:City:PHILLIPSBURG
State:NJ
ZIP:08865
Country:US
Phone:800-582-2537
CAGE:70829

=============  Composition/Information on Ingredients  =============

Ingred Name:DICHROMIC ACID, DIAMMONIUM SALT; (AMMONIUM DICHROMATE)
    (SARA 313) (CERCLA)
CAS:7789-09-5
RTECS #:HX7650000
Fraction by Wt: 99-100%
OSHA PEL:0.1 PPM (CRO3)
ACGIH TLV:0.05 MG/M3 (CR)
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:YES	 OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:EXCESSIVE INHALATION IS
    IRRITATING, MAY CAUSE RESPIRATORY SYSTEM DAMAGE. SKIN/EYE
    CONTACT:SEVERE IRRITATION OR BURNS. INGEST:IS HARMFUL & MAY BE
    FATAL, KIDNEY DAMAGE, LIVER DAMAGE, BURNS T O MOUTH, THROAT &
    STOMACH. CHRONIC:KIDNEY DAMAGE, LIVER DAMAGE. TARGET ORGANS:BLOOD,
    RESPIRATORY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:AMMONIUM DICHROMATE:IARC MONOGRAPHS ON
    EVAL OF CARCIN RISK OF CHEMS TO MAN, VOL 49, PG 49, 1990:GROUP 1.
Effects of Overexposure:HLTH HAZ:SYSTEM, LUNGS, LIVER, KIDNEYS, EYES,
    SKIN, GI TRACT.
Medical Cond Aggravated by Exposure:DAMAGED SKIN.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL MD. IF SWALLOWED, IF CONSCIOUS, GIVE LARGE
    AMOUNTS OF WATER. INDUCE VOMITING. INHAL:REMOVE TO FRESH AIR. IF
    NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS
    DIFFICULT, GIVE OXYG EN. SKIN:IMMEDIATELY FLUSH W/PLENTY OF WATER
    FOR AT LEAST 15 MINUTES. EYE:IMMEDIATELY FLUSH W/PLENTY OF WATER
    FOR AT LEAST 15 MINUTES.

=====================  Fire Fighting Measures  =====================

Flash Point Method:CC
Extinguishing Media:USE WATER SPRAY.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT
    EQUIPMENT . MOVE CNTNRS FROM FIRE AREA IF IT CAN BE DONE W/OUT
    RISK. USE WATER TO KEEP FIRE-EXPOS CNTNRS COOL.
Unusual Fire/Explosion Hazard:STRONG OXIDIZER. CONTACT W/OTHER MATL MAY
    CAUSE FIRE. IN CASES OF EXCESSIVE HEAT/CNDTNS OF CONFINEMENT
    EXTREME HAZARD EXISTS RESULTING IN POSS SPONT (SUPP DATA)

==================  Accidental Release Measures  ==================

Spill Release Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT CLTHG.
    KEEP COMBUSTS (WOOD, PAPER, OIL, ETC) AWAY FROM SPILLED MATL. WITH
    CLEAN SHOVEL, CAREFULLY PLACE MATL INTO CLEAN, DRY CNTNR & COVER;
    REMOVE FROM AREA. FL USH SPILL AREA W/WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CNTNR TIGHTLY CLSD. STORE
    SEPARATELY & AWAY FROM FLAMM & COMBUST MATLS. KEEP FROM CONT
    W/CLTHG. DO NOT GET IN EYES, ON SKIN, ON CLTHG.
Other Precautions:DO NOT BREATHE DUST. USE W/ADEQ VENT. POISON! DANGER!
    MAY CAUSE BURNS/EXTERNAL ULCERS. CAUT! CONTAINS CHROMIUM (VI),
    CANCER HAZARD. MAY BE FATAL IF SWALLOWED/ABSORBED THRU SKIN.
    HARMFUL IF INHALED. ST RONG OXIDIZER. CONT W/OTHER MATL(SUPDAT)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:A NIOSH/MSHA APPROVED RESPIRATOR W/DUST/MIST
    FILTER IS RECOMMENDED. IF AIRBORNE CONCENTRATION EXCEEDS TLV, A
    NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING APPARATUS IS ADVISED.
Ventilation:USE GENERAL OR LOCAL EXHAUST VENTILATION TO MEET TLV
    REQUIREMENTS. VENT HOOD.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA . UNIFORM, APRON ARE REC. LAB COAT.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
PH:3.9 (1% SOLN). EXPLO HAZ:VIOLENT THERMAL DECOMP. OTHER PREC:MAY
    CAUSE FIRE. USE IN CLOSED RXN VESSELS REQUIRES STRINGENT PRECS
    BECAUSE OF EXPLO HAZARD.

==================  Physical/Chemical Properties  ==================

Melt/Freeze Pt:M.P/F.P Text:338F,170C
Vapor Density:8.7
Spec Gravity:2.15 (H*2O=1)
pH:SUPDAT
Solubility in Water:APPRECIABLE (>10%)
Appearance and Odor:SOLID, ORANGE TO RED CRYSTALS; ODORLESS.
Percent Volatiles by Volume:0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG REDUCING AGENTS, COMBUSTIBLE MATERIALS, ORGANIC MATERIALS.
Stability Condition to Avoid:HEAT.
Hazardous Decomposition Products:AMMONIA, CHROMIUM OXIDE FUMES.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE I/A/W ALL APPLICABLE FEDERAL, STATE &
    LOCAL ENVIRONMENTAL REGULATIONS. EPA HAZARDOUS WASTE NUMBER: D001,
    D002 (IGNITABLE, CORROSIVE WASTE).

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.