DURACELL INC TECHNICAL SALES & MARKETING GROUP -- MERCURIC OXIDE CELL -- 6135-00-295-2613
=====================  Product Identification  =====================

Product ID:MERCURIC OXIDE CELL
MSDS Date:09/24/1992
FSC:6135
NIIN:00-295-2613
=== Responsible Party ===
Company Name:DURACELL INC TECHNICAL SALES & MARKETING GROUP
Address:BERKSHIRE INDUSTRIAL PARK BLDG 9
City:BETHEL
State:CT
ZIP:06801
Country:US
Info Phone Num:203-796-4292
Emergency Phone Num:203-796-4654/617-449-7600
CAGE:90303
=== Contractor Identification ===
Company Name:DURACELL INC  TECHNICAL SALES AND MARKETING GROUP
Address:BERKSHIRE CORPORATE PARK
Box:City:BETHEL
State:CT
ZIP:06801
Country:US
Phone:203-796-4000
CAGE:90303
Company Name:ENGINEERED ASSEMBLIES AND COMPONENTS CORP
Address:380 NORTH STREET
Box:City:TETERBORO
State:NJ
ZIP:07608
Country:US
Phone:800-422-8837
CAGE:4J627

=============  Composition/Information on Ingredients  =============

Ingred Name:POTASSIUM HYDROXIDE (CERCLA)
CAS:1310-58-3
RTECS #:TT2100000
Fraction by Wt: 9%
Other REC Limits:NONE SPECIFIED
OSHA PEL:C 2 MG/M3
ACGIH TLV:C 2 MG/M3; 9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:MERCURIC OXIDE (SARA 302/313) (CERCLA)
CAS:21908-53-2
RTECS #:OW8750000
Fraction by Wt: 35-45%
Other REC Limits:NONE SPECIFIED
OSHA PEL:0.1 MG (HG)/M3; Z-2
ACGIH TLV:S,0.025 MG(HG)/M3;96

Ingred Name:MERCURY (SARA 313) (CERCLA)
CAS:7439-97-6
RTECS #:OV4550000
Fraction by Wt: <1%
Other REC Limits:NONE SPECIFIED
OSHA PEL:C, 0.1 MG/M3; Z-2
ACGIH TLV:S,0.025 MG/M3; A4;96
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:ZINC (SARA 313) (CERCLA)
CAS:7440-66-6
RTECS #:ZG8600000
Fraction by Wt: 15%
Other REC Limits:10 MG/M3(MFR)
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:MANGANESE DIOXIDE
CAS:1313-13-9
RTECS #:OP0350000
Fraction by Wt: 6%
Other REC Limits:NONE SPECIFIED
OSHA PEL:5 MG/M3 CEILING
ACGIH TLV:5 MG/M3 (AS MN DUST)

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NOT SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:THESE CHEMICALS ARE CONTAINED IN A
    SEALED CAN. RISK OF EXPOSURE OCCURS ONLY IF THE CELL IS
    MECHANICALLY OR ELECTRICALLY ABUSED. THE MOST LIKELY RISK IS ACUTE
    EXPOSURE WHEN A CELL LEAKS. SKIN CONTACT W ITH CELL CONTENTS CAN
    PRODUCE BURNS. EYE CONTACT CAN RESULT IN SEVERE, PERMANENT DAMAGE.
Explanation of Carcinogenicity:PRODUCT CONTAINS NO INGREDIENTS
    CURRENTLY CLASSIFIED AS CARCINOGENIC BY NTP, IARC OR OSHA.
Effects of Overexposure:SKIN AND EYE CONTACT WITH CELL CONTENTS MAY
    CAUSE CHEMICAL BURNS. AT ELEVATED TEMPERATURES, MERCURY VAPOR MAY
    BE GENERATED, WHICH, IF INHALED, CAN PRODUCE MERCURY INTOXICATION.
Medical Cond Aggravated by Exposure:AN ACUTE EXPOSURE WILL NOT
    GENERALLY AGGRAVATE ANY MEDICAL CONDITIONS.

=======================  First Aid Measures  =======================

First Aid:IF LEAKAGE FROM A CELL COMES INTO CONTACT WITH THE SKIN,
    FLUSH IMMEDIATELY WITH WATER. FOR EYE CONTACT, FLUSH EYES
    IMMEDIATELY WITH COPIOUS WATER FOR 15 MINUTES AND SEE A PHYSICIAN
    AT ONCE. FOR INHALA TION OF MERCURY VAPORS, REMOVE TO FRESHAIR.

=====================  Fire Fighting Measures  =====================

Flash Point:NOT GIVEN
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:NONE SPECIFIED BY MANUFACTURER.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE SELF-CONTAINED
    BREATHING APPARATUS WHEN CELLS ARE INVOLVED IN A FIRE.
Unusual Fire/Explosion Hazard:CELLS MAY RELEASE TOXIC MERCURY VAPOR
    WHEN THE INTEGRITY OF THE CAN IS BROKEN.

==================  Accidental Release Measures  ==================

Spill Release Procedures:AVOID SKIN AND EYE CONTACT. DO NOT INHALE
    VAPORS. ABSORB SPILLED CELL CONTENTS WITH APPROPRIATE ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE AT ROOM TEMPERATURE.
Other Precautions:AVOID MECHANICAL AND ELECTRICAL ABUSE. DO NOT
    RECHARGE. AVOID SHORT CIRCUITS. INSTALL CELLS IN ACCORDANCE WITH
    EQUIPMENT INSTRUCTIONS. OBSERVE CORRECT POLARITY WHEN INSTALLING.
    REPLACE ALL BATTERIES A T THE SAME TIME.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:SELF CONTAINED BREATHING APPARATUS WHEN CELLS
    ARE INVOLVED IN FIRE.
Ventilation:NORMAL VENTILATION. DURING A FIRE SITUATION, PROVIDE AS
    MUCH VENTIALTION AS POSSIBLE.
Protective Gloves:NEOPRENE, RUBBER OR LATEX NITRILE.
Eye Protection:SAFETY GLASSES WHEN HANDLING LEAKERS.
Other Protective Equipment:EMERGENCY EYE WASH STATION AND SHOWER.
Work Hygienic Practices:WASH WITH SOAP AND WATER AFTER HANDLING PRODUCT
    AND BEFORE EATING DRINKING OR SMOKING.
Supplemental Safety and Health
DO NOT MIX BATTERY SYSTEMS SUCH AS ALKALINE AND ZINC CARBON. DO NOT
    CARRY BATTERIES LOOSE IN POCKET, PURSE OR BAG. KEEP AWAY FROM
    CHILDREN. IF SWALLOWED, SEE PHYSICIAN AT ONCE. FOR INFO TREATMENT
    CALL  NATIONAL CAPITOL POISON CENTER AT 202-625-3333 COLLECT.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:NOT GIVEN
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Decomp Temp:Decomp Text:NOT GIVEN
Vapor Pres:NOT GIVEN
Vapor Density:NOT GIVEN
Spec Gravity:NOT GIVEN
Evaporation Rate & Reference:NOT GIVEN
Solubility in Water:NEGLIGIBLE
Appearance and Odor:SOLID BATTERY

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:DO NOT HEAT, DISASSEMBLE, CRUSH, PUNCTURE
    OR RECHARGE
Hazardous Decomposition Products:WHEN HEATED CELLS MAY EMIT HAZARDOUS
    MERCURY VAPORS AND CAUSTIC POTASSIUM HYDROXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
    LOCAL, STATE AND FEDERAL REGULATIONS. DO NOT INCINERATE.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.