CROWN CHEMICAL CORP -- HYDRAULIC OIL 100, 441406 -- 9150-00N068462
===================== Product Identification =====================
Product ID:HYDRAULIC OIL 100, 441406
MSDS Date:12/28/1989
FSC:9150
NIIN:00N068462
=== Responsible Party ===
Company Name:CROWN CHEMICAL CORP
Address:1888 NIRVANA AVENUE
City:CHULA VISTA
State:CA
ZIP:92011
Country:US
Info Phone Num:619-421-6601
Emergency Phone Num:619-294-6000;800-424-9300(CHEMTREC)
CAGE:1194X
=== Contractor Identification ===
Company Name:CROWN CHEMICAL CORP
Address:1888 NIRVANA AVE
Box:City:CHULA VISTA
State:CA
ZIP:92011-6118
Country:US
CAGE:1194X
Company Name:CROWN CHEMICAL CORP
Box:UNKNOW
CAGE:CRWNC
============= Composition/Information on Ingredients =============
Ingred Name:MINERAL OIL, PETROLEUM DISTILLATE, SOLV DEWAXED (SEVERE),
HEAVY PARAFFINIC;(REFINED PETROLEUM OILS). MAY CNTN ING 2/3.
CAS:64742-65-0
RTECS #:PY8038501
Fraction by Wt: <99%
OSHA PEL:5 MG/M3(MFR)
ACGIH TLV:5 MG/M3(MFR)
Ingred Name:MINERAL OIL, SOLVENT REVFINED HEAVY PARAFFINIC, SEVERELY
HYDROTREATED;(REFINED PETROLEUM OILS)
CAS:64741-88-4
RTECS #:PY8040501
Fraction by Wt: <99%
OSHA PEL:5 MG/M3(MFR)
ACGIH TLV:5 MG/M3(MFR)
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: LIQUID IS IRRITATING TO EYES.
SKIN: PRODUCT IS MINIMALLY IRRITATING TO THE SKIN. INHAL: MINIMALLY
IRRITATING IF NOT IN EXCESS OF PERMISSIBLE CONCENTRATIONS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE: HOLD EYELIDS OPEN AND FLUSH WITH PLENTY OF WATER FOR AT
LEAST 15 MINS. GET MED ATTN. SKIN: REMOVE CONTAMD CLTHG & SHOES.
FLUSH SKIN W/WATER. FOLLOW BY WASHING W/SOAP & WATER. IF IRRIT
OCCURS, GET MED ATTN. DO NOT REUSE CLOTHING UNTIL CLEANED. INHAL:
REMOVE TO FRESH AIR. SUPPORT BREATHING(GIVE O*2/ARTF RESP). INGEST:
GET MED ATTN.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:457F,236C
Extinguishing Media:NON FLAMMABLE! SHOULD FIRE OCCUR USE WATER FOG,
FOAM, DRY CHEMICAL, OR CO*2.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT. CLEAR FIRE AREA OF UNPROTECTED PERS. COOL
FIRE-EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
================== Accidental Release Measures ==================
Spill Release Procedures:WARNING! ELIM ALL IGNIT SOURCES. HANDLING
EQUIP MUST BE GROUNDED TO PVNT SPARKING. LGE SPILL: EVAC HAZ AREA
OF UNPROTECTED PERS. WEAR APPROP NIOSH/MSHA APPRVD RESP & PROT
CLTHG. SHUT OFF SOURCE OF LEA K ONLY IF SAFE TO DO SO. DIKE & CNTN.
IF (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STOW CNTNRS IN SAFE NON-TRAFFIC AREA.
KEEP CNTNR CLSD & WELL IDENTIFIED. WHEN TRANS PROD USE BONDING
PROCS. POST NO SMOKING/SIMILAR WARNING SIGNS.
Other Precautions:DO NOT CUT, DRILL, GRIND, WELD/SIMILAR OPS ON/NEAR
EMPTY CNTNRS. KEEP LIQ & VAPS AWAY FROM HEAT SPARKS, FLAME/OTHER
IGNIT SOURCES. VAPS ARE NORM HVR/AIR & CAN BE MOVED BY AIR CURRENTS
TO SURROUNDING A REAS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:AVOID PRLNGD/RPTD BRTHG OF VAPS. USE A
NIOSH/MSHA APPRVD RESP TO AVOID OVEREXP, WHEN ANTIC EXPOS EXCEEDS
OCCUP EXPOS LIMS, USE EITHER AN ATM-SUPPLYING RESP/AN AIR-PURIFYING
RESP FOR ORGANIC VAPORS.
Ventilation:USE EXPLOSION-PROOF VENT AS REQD TO CONTROL VAPOR CONCS.
Protective Gloves:CHEMICAL-RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS.
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA. CHEMICAL-RESISTANT CLOTHES.
Work Hygienic Practices:AIR DRY CONTAMINATED CLOTHING IN A WELL VENTED
AREA. LAUNDER BEFORE USING.
Supplemental Safety and Health
SPILL PROC: VAP CLOUD FORMS, WATER FOG MAY BE USED TO SUPPRESS: CNTN
RUN-OFF. REMOVE W/VACUUM TRUCKS/PUMP TO STOR/SALV VESSEL. SOAK UP
RESIDUE W/AN ABSORB (I.E. VERMICULITE/OTHER SUITABLE MATL). PLACE
IN NON-LEAKING CNTNRS FOR PROPER DISP.FLUSH AREA W/WATER TO REMOVE
TRACE RESIDUE: DISP OF FLUSH SOLNS (ING 8)
================== Physical/Chemical Properties ==================
Spec Gravity:0.880
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR WITH OILY ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:AVOID HEAT, SPARKS, FLAME.
Hazardous Decomposition Products:CARBON MONOXIDE AND UNIDENTIFIED
ORGANIC COMPOUNDS MAY BE FORMED DURING COMBUSTION.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.